We offer a variety of accessories for your Fluke 289 TRMS multimeter.
Utilizing the Rogowski principle, the clamp can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders, or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.
A single range 200 A clamp-on AC current clamp with current output via safety shrouded banana plugs. It is compatible with most Fluke multimeters or any other current measurement device that accepts shrouded banana plugs.
Highly reliable, measures 1 to 1000 A, and provides accurate current reading without breaking the circuit. This clamp measures both AC and DC with a large jaw, battery-powered Hall-effect probe that gives access to difficult to reach areas.
Features built-in fuses for additional measurement protection, 1000 V, 11 A with 20 kA interrupt rating, and the probes allow indication of live voltage even with a blown fuse.
For use with the Fluke 180 Series, 789, 1550B, 1550C, 1555, 53-2-B, 54-2-B and 1653.
Single probe pierces 0.01 to 0.6" (0.25 to 1.5 mm) insulated wire with a small pin allows self-healing of the insulation, and 1000 V, 10 A maximum.
Comes equipped with one pair (red, black) of flat, right angle design for connecting to bus bars, and CAT III 600 V, 5 A rating, CSA listed. Adjustable collar provides two ranges of jaw openings up to 1.81" (30 mm).
Designed to improve steadiness in slippery hands, and is for use with TL222 and TL224 test leads. Rubber over-molded surfaces and finger-hugging curves give a comfortable, reliable grip so you can focus on making an accurate measurement.
Designed to improve steadiness in slippery hands, and is for use with TL222 and TL224 test leads. Rubber over-molded surfaces and finger-hugging curves give a comfortable, reliable grip so you can focus on making an accurate measurement.
Designed to improve steadiness in slippery hands, and is for use with TL222 and TL224 test leads. Rubber over-molded surfaces and finger-hugging curves give a comfortable, reliable grip so you can focus on making an accurate measurement.
Designed to improve steadiness with rubber overmolded surfaces and finger-hugging curves. For use with TL222 and TL224 test leads.
A high-frequency probe designed to convert a DC voltmeter with an input impedance of 10 MΩ into a high frequency (100 kHz to 500 Mhz) RF voltmeter. Additionally, it's probe's DC output is calibrated to equal the RMS value of sine wave input.
Thermocouple converter that accepts the output of any K-type thermocouple and converts it to 1 mV per degree (Celsius or Fahrenheit).
A self-contained temperature-to-voltage converter, this probe is designed to provide a direct temperature reading when it is connected to any high impedance DMM capable of 1 mV resolution, and at least a 300-count full-scale readout capability.
Extension kit for type K thermocouple wires. Includes 3m of thermocouple wire and a pair of male/female mini-connectors.
Features a tapered tip, making this tapered temperature probe ideal for use in air, non-caustic gas, and surface applications.