Fluke 975V Offers
Fluke announces the new 975 AirMeter test tool, redefining how technicians test and monitor HVAC output and indoor air quality.
Combining five tools in one, the Fluke 975 provides instant answers on temperature, humidity, air velocity, CO2, and CO and enables users to quickly generate detailed reports for further analysis. The Fluke 975 is rugged and easy to use, yet powerful enough for the most demanding users.
Use the Fluke 975 to:
- Maximize comfort conditions for building occupants
- Quickly respond to indoor air quality concerns
- Verify the operation of HVAC control systems
- Monitor air flow and velocity to ensure proper ventilation
Why would a customer buy a Fluke 975 AirMeter?
- Optimize HVAC ventilation settings for ASHRAE 62 recommendations.
- Monitor temperature and humidity to meet ASHRAE 55 guidelines.
- Actively monitor conditions that promote a productive environment.
- Quickly and accurately address occupant comfort complaints the first time.
Fluke 975V Specifications
Measured specifications |
Temperature |
Range |
-20 °C to 50 °C (-5 °F to 122 °F) |
Display resolution |
0.1 °C (0.1 °F) |
Accuracy |
± 0.9 °C/± 1.62°F from 40 °C to 60 °C ± 0.5 °C/± 1.00°F from 5 °C to 40 °C ± 1.1 °C/± 1.98 °F from -20 °C to 5 °C |
|
Relative humidity |
Range |
10 % to 90 % RH, non-condensing |
Display Resolution |
1% |
Accuracy |
± 2 % RH (10 % RH to 90 % RH) |
|
Air velocity |
Range |
50.0 fpm to 3000 fpm 0.25 m/sec to 15 m/sec |
Display Resolution |
1 fpm (0.005m/sec) |
Accuracy |
±4 % or 4 fpm* ±4 % or 0.02 m/sec* whichever is greater *Accuracy specification only valid for velocity readings above 50 fpm. |
|
CO2 |
Range |
0 to 500 ppm |
Display Resolution |
1 ppm |
Accuracy |
± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH |
|
Calculated specifications |
Dew point temperature |
Range |
-44 °C to 50 °C, (-47 °F to 122 °F) |
Display Resolution |
0.1 °C (0.1 °F) |
Accuracy |
± 1 °C when temp: -20 °C to 50 °C RH: 40 % to 90 % ± 2 °C when temp: -20 °C to 50 °C RH: 20 % to 40 % ± 4 °C when RH: 10 % to 20 % |
|
Wet bulb temperature |
Range |
-16 °C to 50 °C, (3 °F to 122 °F) |
Display Resolution |
0.1 °C, (0.1 °F) |
Accuracy |
± 1.2 °C when RH: 20 % to 90 % temp: -20 °C to 60 °C ± 2.1 °C when RH: 10 % to 20 % |
|
Volume flow rate (in a duct) |
Range |
0 to 3,965 M3/m, (0 to 140,000 cfm) |
Display Resolution |
0.001 M3/min, (1 cfm) |
Accuracy |
N/A: The volume flow calculation will be a simple average of the data points times the duct area |
|
% outside air (based on temperature) |
Range |
0 to 100% |
Display Resolution |
0.1 |
|
% outside air (based on CO2) |
Range |
0 to 100 % |
Display Resolution |
0.1 % N/A |
|
General specifications |
Operating and storage temperature |
|
-20 °C to 50 °C (-4 °F to 122 °F) |
|
Humidity |
|
10 % to 90 % (non-condensing) |
|
Altitude | |
Shock and vibration | |
Multi-language interface |
|
English, French, Spanish, Portuguese and German |
|
Battery |
|
Rechargeable Li-Ion (primary), three-AA (backup) |
|
Data logging |
|
25,000 records (continuous), 99 records (discrete) |
|
Warranty | |
Click here for complete specifications on the Fluke 975V
What's included with the Fluke 975V
- Fluke 975V AirMeter w/ Air Velocity Probe