Model: 115 | Order No: 115/EFSP
Ideal for electrical and electronic testing applications, this True RMS meter also comes equipped with simple, one-handed operation and compact design. Additionally, it measures True RMS voltage and current with 6000 count resolution as well as resistance, continuity, frequency, and capacitance.
Designed by electricians. Engineered by Fluke.
Compact true-rms meter for field service technicians. The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications.
Also check out the Fluke 114 Electrical Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117, the Electrician's Multimeter with Non-contact voltage.
DC Millivolts | |
Range | 600 mV |
Resolution | 0.1 mV |
Accuracy | 0.5% + 2 |
DC Volts | |
Range | 6 V 60 V 600 V |
Resolution | 0.001 V 0.01 V 0.1 V |
Accuracy | 0.5% + 2 |
Auto Volts | |
Range | 600 V |
Resolution | 0.1 V |
Accuracy | 2.0% + 3 (dc 45 to 500 Hz) 4.0% + 3 (500 Hz to 1kHz) |
AC Millivolts1 True RMS | |
Range | 600 mV |
Resolution | 0.1 mV |
Accuracy | 1.0% + 3 (dc 45 to 500 Hz) 2.0% + 3 (500 Hz to 1kHz) |
AC Volts1 True RMS | |
Range | 6 V 60 V 600 V |
Resolution | 0.001 V 0.01 V 0.1 V |
Accuracy | 1.0% + 3 (dc 45 to 500 Hz) 2.0% + 3 (500 Hz to 1kHz) |
Continuity | |
Range | 600 Ω |
Resolution | 1 Ω |
Accuracy | Beeper on <20 off> 250; detects opens or shorts of 500 µs or longer |
Ohms | |
Range | 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 40 MΩ |
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.001 MΩ 0.01 MΩ |
Accuracy | 0.9% + 2 0.9% + 1 5% + 2 |
Diode Test | |
Range | 2 V |
Resolution | 0.001 V |
Accuracy | 0.9% + 2 |
Capacitance | |
Range | 1000 nF 10 µF 100 µF 9999 µF 100 to 1000 µF >1000 µF |
Resolution | 1 nF 0.01 µF 0.1 µF 1 µF |
Accuracy | 1.9% + 2 1.9% + 2 5% + 20 |
Lo-Z capacitance | |
Range | 1 nF to 500 µF |
Accuracy | 10% + 2 typical |
AC Amps True RMS (45 to 500 Hz) | |
Range | 6 A 10 A 20 A overload for 30 seconds max |
Resolution | 0.001 A 0.01 A |
Accuracy | 1.5% + 3 |
DC Amps | |
Range | 6 A 10 A 20 A overload for 30 seconds max |
Resolution | 0.001 A 0.01 A |
Accuracy | 1.0% + 3 |
Hz (V or A Input)2 | |
Range | 99.99 Hz 999.9 Hz 9.999 kHz 50.00 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
Accuracy | 0.1% + 2 |
Click on a category to view a selection of compatible accessories with the Fluke 115 True RMS Digital Multimeter.