Model: 116-NIST
Comes with temperature and microamp measurements, making this multimeter ideal for HVAC/R professionals. This product also measures resistance, continuity, frequency, and capacitance and features a built-in thermometer.
This product includes a Traceable Calibration Certificate with full Data and Uncertainties.
Features
Applications
Facilities maintenance professionals face a wide range of challenges, from electrical and mechanical equipment uptime to overall safety concerns. It’s critical to maintain facilities and the associated assets at peak performance. Let's review the issues faced by maintenance managers, IT support, and electrical/mechanical technicians. Along with the Fluke solutions that offer to save you time and money while increasing efficiency and safety. Fluke makes reliable, rugged and accurate tools to maintain electromechanical systems, motors, pumps, electrical distribution systems and more to keep your world up and running.
Learn MoreAccuracy Specifications | |
DC Millivolts | Range: 600.0 mV Resolution: 0.1 mV Accuracy: 0.5 % + 2 |
DC Volts | Range: 6, 60, 600 V Resolution: 0.001, 0.01, 0.1 V Accuracy: 0.5 % + 2 |
Auto Volts | Range: 600.0 V Resolution: 0.1 V Accuracy: 2.0 % + 3 (dc, 45 to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
AC millivolts True RMS | Range: 600.0 mV Resolution: 0.1 V Accuracy: 1.0 % + 3 (dc, 45 to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
AC Volts True RMS | Range: 6, 60, 600 V Resolution: 0.001, 0.01, 0.1 V Accuracy: 1.0 % + 3 (dc, 45 to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
Continuity | Range: 600 Ω Resolution: 1 Ω Accuracy: Beeper on <20 Ω off> 250 Ω; detects opens or shorts of 500 µs or longer |
Ohms | Range: 600 Ω, 6, 60, 600 kΩ, 6, 40 MΩ Resolution: 1 Ω, 0.001, 0.01, 0.1 kΩ, 0.001, 0.01 MΩ Accuracy: 0.9 % + 1 |
Diode Test | Range: 2.000 V Resolution: 0.001 V Accuracy: 0.9 % + 2 |
Capacitance | Range: 1000, nF, 10, 100, 9999, 100 to 1000, >1000 µF Resolution: 1 nF, 0.01, 0.1, 1 µF Accuracy: 0.9 % + 2, 1.9 % + 2, 5 % + 20 |
Lo-Z Capacitance | Range: 1 nF to 500µF Accuracy: 10 % + 2 typical |
Temperature (Type-K Thermocouple) | Range: -40 to 752 °F (-40 to 400 °C) Resolution: 0.2 °F (0.1°C) Accuracy: 1 % + 18 |
AC µAmps True RMS (45 to 500 Hz) | Range: 600.0 µA Resolution: 0.1 µA Accuracy: 1.5 % + 3 (2.5 % + 3 >500 Hz |
DC µAmps | Range: 600.0 µA Resolution: 0.1 µA Accuracy: 1.0 % + 2 |
Hz (V or A input) | Range: 99.99, 999.9 Hz, 9.999, 50.00 kHz Resolution: 0.01, 0.1 Hz, 0.001, 0.01 kHz Accuracy: 0.1 % + 2 |
General Specifications | |
Maximum Voltage Between any Terminal and Earth Ground | 600 V |
Display | Digital: 6,000 counts, updates 4/sec |
Bar Graph | 33 segments, updates 32/sec |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Storage Temperature | -40 to 140°F (-40 to 60°C) |
Battery | 9 V Alkaline, NEDA 1604A/IEC 6LR61 |
Battery Life | 400 hours typical, without backlight |
Surge Protection | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
Click on a category to view a selection of compatible accessories with the Fluke 116 HVAC/R Multimeter with temperature and microamps,.