Fluke 8845A 120V Offers
The Fluke 8845A Bench Top 6.5 digit Precision Multimeter has the precision and versatility to handle your most demanding measurements, on the bench or in a system. These meters are both high performance and feature rich, yet also remarkably easy to use.
The Fluke 8845A Bench Top 6.5 digit Precision Multimeter performs the functions you would expect to see in a multifunction DMM, including measuring volts, ohms, and amps. Basic V dc accuracy of up to 0.0024 %, 10 A current range, and a wide ohms range give you an unbeatable combination of measurement capability.
You can also use the the Fluke 8845A Bench Top 6.5 digit Precision Multimeter to measure frequency and period. The functions of a counter, capacitance meter, and thermometer are built in for unparalleled versatility. Extend the meters' utility even more with their graphical display modes, including Trendplot paperless recorder mode, statistics and histograms-features you won't find on other multimeters.
Of course, the meter is also durable and dependable, features you expect from any Fluke meter. This unique combination of features and performance makes the Fluke 8845A Bench Top 6.5 digit Precision Multimeter an unbeatable value for a wide variety of applications, including manufacturing test, research and development, and service.
Fluke 8845A 120V Specifications
| Technical Specifications |
| Display |
|
| |
VFD Dot Matrix |
| Resolution |
|
| |
6.5 Digits |
| V DC |
| Ranges | 100 mV to 1000 V | | Max. Resolution | 100 nV | | Accuracy | 8845A: 0.0035 + 0.0005 |
| 8846A: 0.0024 + 0.0005 | |
| Ranges |
100 mV to 1000 V |
| Max. Resolution |
100 nV |
| Accuracy |
8845A: 0.0035 + 0.0005 |
| |
8846A: 0.0024 + 0.0005 |
| V AC |
| Ranges | 8845A: 100 mV to 750 V |
| 8846A: 100 mV to 1000 V | | Max. Resolution | 100 nV | | Accuracy | 8845A: 0.06 + 0.03 |
| 8846A: 0.06 + 0.03 | | Frequency | 3 Hz to 300 KHz | |
| Ranges |
8845A: 100 mV to 750 V |
| |
8846A: 100 mV to 1000 V |
| Max. Resolution |
100 nV |
| Accuracy |
8845A: 0.06 + 0.03 |
| |
8846A: 0.06 + 0.03 |
| Frequency |
3 Hz to 300 KHz |
| Resistance |
| 2x4 Wire | Yes | | Ranges | 8845A: 100 Ω to 100 MΩ |
| 8846A: 10 Ω to 1 GΩ | | Max. Resolution | 8845A: 100 μΩ |
| 8846A: 10 μΩ | | Accuracy | 8845A: 0.010 + 0.001 |
| 8846A: 0.010 + 0.001 | |
| 2x4 Wire |
Yes |
| Ranges |
8845A: 100 Ω to 100 MΩ |
| |
8846A: 10 Ω to 1 GΩ |
| Max. Resolution |
8845A: 100 μΩ |
| |
8846A: 10 μΩ |
| Accuracy |
8845A: 0.010 + 0.001 |
| |
8846A: 0.010 + 0.001 |
| A DC |
| Ranges | 100 μA to 10 A | | Max. Resolution | 100 pA | | Accuracy | 0.050 + 0.005 | |
| Ranges |
100 μA to 10 A |
| Max. Resolution |
100 pA |
| Accuracy |
0.050 + 0.005 |
| A AC |
| Ranges | 8845A: 10 mA to 10 A |
| 8846A: 100 mA to 10 A | | Max. Resolution | 8845A: 10 nA |
| 8846A: 100 pA | | Accuracy | 0.10 + 0.04 | | Frequency | 3 Hz to 10 kHz | |
| Ranges |
8845A: 10 mA to 10 A |
| |
8846A: 100 mA to 10 A |
| Max. Resolution |
8845A: 10 nA |
| |
8846A: 100 pA |
| Accuracy |
0.10 + 0.04 |
| Frequency |
3 Hz to 10 kHz |
| Freq/Period |
| Ranges | 8845A: 3 Hz to 300 kHz |
| 8846A: 3 Hz to 1 MHz | | Max. Resolution | 1 μHz | | Accuracy | 0.01 % | |
| Ranges |
8845A: 3 Hz to 300 kHz |
| |
8846A: 3 Hz to 1 MHz |
| Max. Resolution |
1 μHz |
| Accuracy |
0.0001 |
| Continuity/ Diode Test |
|
| |
Yes |
| Capacitance |
| Ranges | 8846A: 1 nF to 0.1 F | | Max. Resolution | 8846A: 1 pf | | Accuracy | 8846A: 1 % | |
| Ranges |
8846A: 1 nF to 0.1 F |
| Max. Resolution |
8846A: 1 pf |
| Accuracy |
8846A: 1 % |
| Temperature |
| Type | 8846A: Platinum RTD | | Ranges | 8846A: -200°C to +600° | | Max. Resolution | 8846A: 0.01° | | Accuracy | 8846A: 0.06° | |
| Type |
8846A: Platinum RTD |
| Ranges |
8846A: -200°C to +600° |
| Max. Resolution |
8846A: 0.01° |
| Accuracy |
8846A: 0.06° |
| Math Functions |
| NULL, Min/Max/Average, Std Dev | | dB/dBm | Yes | |
| |
NULL, Min/Max/Average, Std Dev |
| dB/dBm |
Yes |
| Advanced Functions |
| Statistics/Histogram | Yes | | Trendplot | Yes | | Limit Test | Yes | |
| Statistics/Histogram |
Yes |
| Trendplot |
Yes |
| Limit Test |
Yes |
| Input Output |
| USB Memory | 8846A: USB memory drive port | | Real Time Clock | 8846A: Yes | | Interfaces | RS 232, IEE-488.2, Ethernet, USB (with optional adaptor) | | Programming Languages/Modes | 8846A: SCPI (IEEE-488.2), Agilent 34401A, Fluke 45 | |
| USB Memory |
8846A: USB memory drive port |
| Real Time Clock |
8846A: Yes |
| Interfaces |
RS 232, IEE-488.2, Ethernet, USB (with optional adaptor) |
| Programming Languages/Modes |
8846A: SCPI (IEEE-488.2), Agilent 34401A, Fluke 45 |
| General Specifications |
| Weight |
|
| |
3.6 kg (8.0 lbs) |
| Dimensions |
| 88 mm x 217 mm x 297 mm (3.46 in x 8.56 in x 11.7 in) |
|
| |
88 mm x 217 mm x 297 mm (3.46 in x 8.56 in x 11.7 in) |
| Safety |
| Designed to comply with IEC 61010-1 2000-1, ANSI/ISA-S82.01-1994, CAN/CSA-C22.2 No. 1010.1-92 CAT I 1000 V, CAT II 600 V |
|
| |
Designed to comply with IEC 61010-1 2000-1, ANSI/ISA-S82.01-1994, CAN/CSA-C22.2 No. 1010.1-92 CAT I 1000 V, CAT II 600 V |
| Warranty |
|
| |
One year |
Click here for complete specifications on the Fluke 8845A 120V
What's included with the Fluke 8845A 120V
- TL71 Test Lead Set, Premium DMM
- LCI Line Core
- USB to RS232 Cable Adapter
- WEEE Information Sheet
- Warranty Information
- Programmer, Users and Service Manuals (CD-ROM)
- FlukeView Forms - Basic for 8845/8846