1.800.561.8187

information@ITM.com

Customer Reviews
 
 

Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit

Model: 1587/MDT FC | Order No: 1587/MDTFC

Ideal for troubleshooting and preventative maintenance, this insulation multimeter comes in a compact, handheld design, and features True RMS capabilities. Additionally, this kit comes supplied with the i400 current clamp and 9040 phase rotation indicator.

Traceable Calibration Certificate for your 1587 FC


Traceable Calibration Certificate for your I400


Traceable Calibration Certificate for your 9040


$2,133.83 CAD

Availability:
2 to 3 Weeks




Fluke 1587-MDT FC Offers

FLUKE 1587 FC Insulation Tester

  • PI/DAR timed ratio tests (1587 FC only)
  • Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
  • VFD low-pass filter for accurate motor drive measurements (1587 FC only)
  • Auto-discharge of capacitive voltage for added user protection
  • Insulation test (1587 FC: 0.01 MΩ to 2 GΩ) (1577: 0.1 MΩ to 600 MΩ)
  • Insulation test voltages (1587 FC: 50 V, 100 V, 250 V, 500 V, 1000 V),(1577: 500 V, 1000 V) for many applications
  • AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance (Ω), Continuity
  • Capacitance, diode test, temperature, Min/Max, frequency (Hz)(1587 FC only)
  • Auto power off to save battery power
  • CAT III 1000 V, CAT IV 600 V measurement category
  • Rugged, utility hard case allows you to bring everything you need for the job
  • Large display with backlight

FLUKE i400 AC Current Clamp

  • Companion to your DMM to measure up to 400 A AC
  • 1mA/Amp output guarantees easy reading on you meter
  • Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating
  • Specially designed to offer maximum utility in a very compact shape

FLUKE 9040 Phase Rotation Indicator

  • 3 phase indication
  • Indication of phase rotation
  • Clear LCD display
  • No battery required

Fluke 1587/MDT FC Specifications

AC Voltage Measurements
Range 600 mV
6 V
60 V
600 V
1000 V
Resolution 0.1 mV
0.001 V
0.01 V
0.1 V
1 V
50 to 60 Hz ±(% of Rdg + counts) ±(1% + 3)
±(1% + 3)
±(1% + 3)
±(1% + 3)
±(2% + 3)
60 to 5000 Hz ±(% of Rdg + counts) ±(2% + 3)
±(2% + 3)
±(2% + 3)
±(2% + 3)1
±(2% + 3)1
Low-Pass Filter Voltage
Range 600 mV
6 V
60 V
600 V
1000 V
Resolution 0.1 mV
0.001 V
0.01 V
0.1 V
1 V
50 to 60 Hz ±(% of Rdg + counts) ±(1% + 3)
±(1% + 3)
±(1% + 3)
±(1% + 3)
±(2% + 3)
60 to 400 Hz ±(% of Rdg + counts) ±(2% + 3) - (6% - 3)
±(2% + 3) - (6% - 3)
±(2% + 3) - (6% - 3)
±(2% + 3) - (6% - 3)
±(2% + 3) - (6% - 3)
DC Voltage Measurement
Range 6 V dc
60 V dc
600 V dc
1000 V dc
Resolution 0.001 V
0.01 V
0.1 V
1 V
Accuracy ±(% of Rdg + Counts) ±(0.09% + 2)
±(0.09% + 2)
±(0.09% + 2)
±(0.09% + 2)
Input Impedance 10 MΩ (nominal), <100 pF
Nominal Mode Rejection Ratio >60 dB at 50 or 60 Hz
Common Mode Rejection Ratio >120 dB at dc, 50 or 60 Hz (1 k unbalance)
DC Millivolts Measurement
Range 600 mVdc
Resolution 0.1 mV
Accuracy ±(% of Rdg + Counts) ±(0.1 + 1)
DC and AC Current Measurement
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)1
Burden Voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)1
Burden Voltage (Typical) 2 mV/mA
DC
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden Voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden Voltage (Typical) 2 mV/mA
Overload 600 mA for 2 minutes maximum
Fuse Protection for mA Input 0.44 mA, 1000 V, IR 10 kA
AC Conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input
Ohms Measurement
Range 600 Ω
6 kΩ
60 kΩ
600 kΩ
6 MΩ
50 MΩ
Resolution 0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Accuracy +(% of Rdg+Counts)1 ±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(1.5% + 3)
Overload Protection 1000 rms or dc
Open Circuit Test Voltage <8 V dc
Short Circuit Current <1.1 mA
Diode Test
Diode Test Indication Display voltage drop: 0.6 V at1.0 mA nominal test current
Accuracy ±(2% + 3)
Continuity Test
Continuity Indication Continuous audible tone for testresistance below 25 Ω and off above 100 Ω
Maximum reading: 1000 Ω
Open Circuit Voltage <8.0 V
Short Circuit Current 1.0 mA typical
Overload Protection 1000 V rms
Response Time >1 m sec
Frequency Measurement
Range 99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
Resolution 0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
Accuracy ±(% of Rdg+Counts) ±(0.1% + 1)
±(0.1% + 1)
±(0.1% + 1)
±(0.1% + 1)
Frequency Counter Sensitivity
600.0 mV ac V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 mV
V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 150.0 mV
DC Trigger Levels¹ to 20 kHz2: NA
6.0 V V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 1.0 V
V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 1.5 V
DC Trigger Levels¹ to 20 kHz2: -400.0 mV and 2.5 V
60.0 V V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 10.0 V
V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 36.0 V
DC Trigger Levels¹ to 20 kHz2: 1.2 V and 4.0 V
600.0 V V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 V
V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA
DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V
1000.0 V V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 300.0 V
V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA
DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V
Capacitance
Range 1000 nF
10.00 µF
100.0 µF
9999 µF
Resolution 1 nF
0.01 µF
0.1 µF
1 µF
Accuracy ±(% of Rdg+Counts) ±(1.2% + 2)
±(1.2% + 2)
±(1.2% ± 90 counts)
±(1.2% ± 90 counts)
Temperature Measurement
Range -40 to 998°F (-40 to 537°C)
Resolution 0.1°F (0.1°C)
Accuracy ±(% of Rdg+Counts)1 ±(1% + 10 counts)
±(1% + 18 counts)
Insulation Specifications
Measurement Range 0.01 MΩ to 2 GΩ
Test Voltages 50, 100, 250, 500, 1000 V
Test Voltage Accuracy 20%, 0%
Short-Circuit Test Current 1 mA nominal
Auto Discharge Discharge time <0.5 second for C=1 µF or less
Live Circuit Detection Inhibit test if terminal voltage >30 V prior to initialization of test
Maximum Capacitive Load Operable with up to 1 µF load
Output Voltage
50 V (0% to +20%) Display range: 0.01 to 6.00 MΩ
Resolution: 0.01 MΩ
Test current: 1 mA at 50 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 50.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 50 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
100 V (0% to +20%) Display range: 0.01 to 6.00 MΩ
Resolution: 0.01 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 100.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
250 V (0% to +20%) Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 250 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
500 V (0% to +20%) Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 500 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 500 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
1000 V (0% to +20%) Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 600 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 0.6 to 2.0 GΩ
Resolution: 100 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(10% + 3 counts)
Click here for complete specifications on the Fluke 1587/MDT FC

Fluke 1587FC Insulation Multimeter

Ideal for troubleshooting and preventative maintenance, this insulation multimeter comes in a compact, handheld design, and features True RMS capabilities. Additionally, this tool is compatible with the Fluke Connect app, which allows the user to see and share measurement results wirelessly with their smartphone or tablet.


Fluke i400 AC Current Clamp, 400 A AC, CAT IV 600 V/CAT III 1000 V

Compatible with digital multimeters, this current clamp measures up to 400 A AC and features a 1 mA/A output that guarantees easy reading on your meter. In addition, this clamp provides precise current measurements without breaking electric circuits, helping you measure safely with industry-standard safety ratings.


Fluke 9040 Phase Rotation Indicator

Phase Rotation Indicator for industrial applications. The Fluke 9040 Phase Rotation Indicator is a portable handheld instrument designed to detect the rotary field of three-phase systems. With three test leads, this rugged tester easily determines a clockwise or counterclockwise direction.

What's included with the Fluke 1587/MDT FC

  • 1587 FC Insulation Multimeter
  • i400 Current Clamp
  • 9040 Phase Rotation Indicator
  • Remote probe
  • Test leads
  • Alligator clips
  • K-type thermocouple
  • Hard case
  • User documentation
Fluke 1587 FC Insulation Multimeter Fluke 1577 Insulation Multimeter Fluke 1503 Insulation Resistance Meter Fluke 1507 Insulation Resistance Tester Fluke 1550C Insulation Resistance Tester Fluke 1555 Insulation Resistance Tester
Two in one tools Stand-alone tools
Insulation test features 1587 FC 1577 1503 1507 1550C 1555
Test voltages 50 V, 100 V, 250 V, 500 V, 1000 V 500 V, 1000 V 500 V, 1000 V 50 V, 100 V, 250 V, 500 V, 1000 V 250 V to 5000 V 250 V to 10,000 V
Insulation resistance range 0.01 MΩ to 2 GΩ 0.01 MΩ to 600 GΩ 0.01 MΩ to 2000 GΩ 0.01 MΩ to 10 GΩ 250 kΩ to 1 TΩ 250 kΩ to 2 TΩ
PI/DAR
Auto discharge
Timed ramp test (Breakdown)
Pass/fail comparison
Est. # of IRT tests 1000 1000 2000 2000 Various Various
Voltage > 30 V warning
Memory With Fluke Connect App
Remote test probe
Lo ohms/earth-bond continuity 200 mA source (10 mΩ resolution) 200 mA source (10 mΩ resolution)
Display Digital LCD Digital LCD Digital LCD Digital LCD Digital LCD/ analog display Digital LCD/ analog display
Hold/lock
Multimeter features
AC/DC volts

Note: Not all product features and specifications are listed in this table. For more complete information, see individual product data sheets.

Footnotes:
1. Function useful for checking connections and motor windings. Also useful for users who are required to perform earth-bond continuity measurements during installation testing.
2. Filter for variable-speed motor drive measurements.

Current
Resistance
Continuity beeper
Temperature (contact)
Lo-pass filter2
Capacitance
Diode test
Frequency
MIN/MAX
Other features
Backlight
Software Fluke Connect compatible FlukeView® Forms Basic Fluke View® Forms Basic
Battery 4 AA (NEDA 15A or IEC LR6) 4 AA (NEDA 15A or IEC LR6) 4 AA (NEDA 15A or IEC LR6) 4 AA (NEDA 15A or IEC LR6) Rechargeable Rechargeable
Find out more about insulation testing
This product features Fluke Connect Technology

See it. Save it. Share it. All the facts, right in the field.

Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.

Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.

Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.


Fluke Connect Features:

  • TrendIt™ Graphs: Use graphing to show changes in measurements, allowing you to graph and show problems instantly.
  • EquipmentLog™ History: Access equipment history building a database of equipment health and baselines with cloud backup.
  • ShareLive™ Video Calls: Save, collaborate and share measurements instantly with your team anytime, from anywhere.
  • AutoRecord™ Measurements: Instantly save measurements to your phone with Cloud backup.
  • Fluke Cloud™ Storage: Securely access equipment records anywhere, anytime.

Fluke Connect Benefits:

  • Maximize uptime
  • Minimize maintenance costs
  • Better assessments with accurate records
  • Higher efficiency with less walking around; no notebook and excel needed
  • Share troubleshooting knowledge live
  • Create and share helpful content in the field
  • Access to Fluke digital product manuals means no need to carry manuals in the field
  • Keep organized manually entered measurements

Why you need the Fluke 1587 FC Insulation Multimeter


Insulation multimeters are an integrated tool for maintaining and troubleshooting motor systems, electrical distribution, and production equipment. Carrying the Fluke 1587 FC will enable you to test insulation more often, making your maintenance tests more thorough and your troubleshooting more effective.<br/><br/>This multimeter combines a TRMS digital multimeter and a digital insulation tester in a single, compact unit. For this reason, it is capable of measuring a higher resistance than the average multimeter; allowing you to know when a cable is leaking under high voltage - see 0:25.<br/><br/>Its compatibility with Fluke Connect® makes it even more of an asset in your toolbox! Find out why at 0:58.

Fluke 1587 FC Tips and Tricks: Low-Pass Filter


Get step-by-step instructions on using a VFD drive and the 1587 FC. By connecting the unit to a smartphone or tablet via Bluetooth, you can see your measurements in current time.

How To Test a Motor with the Fluke 1587 FC Insulation Meter


Use the Fluke Connect App to save the measurements taken for a later date. To test a motor, follow the simple step-by-step instructions provided in the video. You'll complete a motor test in no time at all.

How To Take Insulation Resistance Measurements with the Fluke 1587FC


This video will teach the viewers how to take insulation resistance measurements with this insulation multimeter. It also shows the viewers where functions that relate to insulation resistance are on the device. Additionally, this test instrument is Fluke Connect compatible.

Accessories

Click on a category to view a selection of compatible accessories with the Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.
$127.78 CAD

was $156.79


Learn More

Fluke C25 Large Soft Carrying Case for digital multimeters C25
Durable, zippered carrying case with padding and inside pocket, and high quality polyester exterior. It includes a convenient hand strap and carries most of Fluke's popular digital multimeters.
$65.03 CAD

was $79.79


Learn More

Fluke TPAK ToolPak Magnetic Meter Hanger ToolPak
Hang your meter in a variety of ways for convenient hands-free operation. Attaches to most Fluke meters.
$60.95 CAD

was $74.79


Learn More

Fluke TL220 Suregrip Industrial Test Lead Set TL220
Includes the Fluke AC220, Fluke TP220, and Fluke TL224.
$121.92 CAD

was $149.59


Learn More

Fluke TL175 TwistGuard Test Leads Set TL175
Built from WearGuard lead wire and silicone insulation, this test lead has an adjustable tip shroud that retracts and extends from 0.75 to 0.16" when you twist it. Additionally, the patented TwistGuard design allows easy adjustments to reduce or increase tip exposure to comply with new electrical safety requirements.
$50.98 CAD

was $62.55


Learn More

Fluke i400 AC Current Clamp, 400 A AC, CAT IV 600 V/CAT III 1000 V I400
Compatible with digital multimeters, this current clamp measures up to 400 A AC and features a 1 mA/A output that guarantees easy reading on your meter. In addition, this clamp provides precise current measurements without breaking electric circuits, helping you measure safely with industry-standard safety ratings.
$243.02 CAD

was $298.19


Learn More


Ask a question about the Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit :