Model: V3000 FC Kit | Order No: V3000FC-KIT
Includes the V3000 FC Wireless AC Voltage Module and Fluke 3000 FC Multimeter with Fluke Connect wireless functionality.
Fluke Connect Enabled Kit with wireless AC Voltage module. Includes the V3000 module and 3000 FC Multimeter.
Fluke Connect enabled True-RMS AC Voltage Module
This fully functional True-RMS voltage meter that wirelessly relays AC voltage measurements to other Fluke Connect enabled master units.
The Fluke v3000 FC is capable of measuring up to 1000V while logging up to 65,000 readings. The V3000 FC includes a set of TL224 Test Leads, AC285 Alligator Clips and a magnetic hanging strap.
The multimeter at the core of the Fluke Connect suite of tools.
The Fluke 3000FC Digital Multimeter is part of the Fluke Connect system of test tools, communicating with the new Fluke connect mobile app available for Android™ or iOS smart phones. The 3000FC wireless digital multimeter functions as the mobile hub, displaying readings from up to three module tools simultaneously from 20 meters away. Fluke Connect modules also give you the flexibility to build your wireless test tool system how you want it.
By seeing multiple measurements at the same time, troubleshooters can see cause and effect, interactions between inputs/outputs or other measurement points, simultaneously and remotely.For those who need to see more than 3 measurements at a time, the addition of the PC3000 FC Adapter allows for up to 10 modules to be viewed at any time on a PC.
The Fluke 3000FC meets measurement category 1000V CAT III and Category IV 600V safety standards.
Range1 | Resolution | Accuracy2,3,4 | |
---|---|---|---|
45 Hz to 500 Hz | 500 Hz to 1 kHz | ||
6.000 V | 0.001 V | 1.0 % + 3 | 2.0 % + 3 |
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
1000 V | 1 V |
LCD w/backlight | 3.5 digits, 6000 counts, updates 4/sec |
---|---|
Battery type | 2 AA, NEDA 15 A, IEC LR6 |
Battery life | 400 Hours |
Memory | Record up to 65000 readings |
RF communications | 2.4 GHZ ISM Band |
RF communication range | Open air, unobstructed: Up to 20 m Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m |
Operating temperature | -10 °C to +50 °C |
Storage temperature | -40 °C to +60 °C |
Temperature coefficient | 0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C) |
Operating humidity | 90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C |
Altitude | Operating: 2,000 m Storage: 12,000 m |
EMC | EN 61326-1:2006 |
Safety compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 |
Safety rating | CAT IV 600 V, CAT III 1000 V |
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE |
Ingress Protection (IP) rating | IP42 |
Pollution Degree | 2 |
Size (HxWxD) | 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) |
Weight | .22 kg (8 oz) |
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
Accuracy 2,3,4 | |||
---|---|---|---|
Range1 | Resolution | 45 Hz to 500 Hz | 500 Hz to 1 kHz |
600.0 mV | 0.1 mV | 1.0 % + 3 | 2.0 % + 3 |
6.000 V | 0.001 V | ||
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
1000 V | 1 V |
1 All ac voltage ranges are specified from 1 % of range to 100 % of range.
2 Crest factor of < 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3 For non-sinusoidial waveforms, add ± (2 % of reading + 2 % full scale) typical, for crest factor up to 3.
4 Do not exceed 107 V-Hz.
Function | Range | Resolution | Accuracy |
---|---|---|---|
mV | 600.0 mV | 0.1 mV | 0.09 % + 2 |
V | 6.000 V | 0.001 V | 0.09 % + 2 |
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
1000 V | 1 V | 0.15 % + 2 | |
Ω | 600 Ω | 1 Ω | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 µs or longer. |
Ω | 600.0 Ω | 0.1 Ω | 0.5 % + 2 |
6.000 kΩ | 0.001 kΩ | 0.5% + 1 | |
60.00 kΩ | 0.01 kΩ | ||
60.00 kΩ | 0.1 kΩ | ||
600.0 kΩ | 0.001 MΩ | ||
50.00 MΩ | 0.01 MΩ | 1.5 % + 3 | |
Diode test | 2.000 V | 0.001 V | 1 % + 2 |
µF | 1000 nF | 1 nF | 1.2 % + 2 |
10.00 µF | 0.01 µF | ||
100.0 µF | 0.1 µF | ||
9999 µF1 | 1 µF | 10 % typical |
1 In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2 % + 2.
Function | Range1 | Resolution | Accuracy |
---|---|---|---|
mA AC (45 Hz to 1 kHZ) | 60.00 mA | 0.01 mA | 1.5 % + 3 |
400.0 mA3 | 0.1 mA | ||
mA DC2 | 60.00 mA | 0.01 mA | 0.5 % + 3 |
400.0 mA3 | 0.1 mA |
1 All ac current ranges are specified from 5 % of range to 100 % of range.
2 Input burden voltage (typical): 400 mA input 2 mV/mA.
3 400.0 mA accuracy specified up to 600 mA overload.
Range | Resolution | Accuracy [1] |
---|---|---|
99.99 Hz | 0.01 Hz | 0.1 % + 1 |
999.9 Hz | 0.1 Hz | |
9.999 kHz | 0.001 kHz | |
99.99 kHz | 0.01 kHz |
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Function | Accuracy |
---|---|
DC functions | The specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration. |
AC functions | The specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration. |
Maximum voltage between any terminal and earth ground | 1000 V dc or ac rms |
---|---|
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only |
Display (LCD) | Update rate: 4/sec Votls, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts |
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 |
Battery life | 250 hours minimum |
RF communications | 2.4 GHZ ISM Band |
RF communication range | Open air, unobstructed: Up to 20m Obstructed, sheetrock wall: Up to 6.5m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m |
Temperature | Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C |
Temperature coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
Relative humidity | 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C) |
Altitude | Operating: 2,000 m Storage: 12,000 m |
Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
Safety compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 |
Certifications | CSA, FCC, CE |
Ingress Protection (IP) rating | IP54 |
Pollution Degree | 2 |
Size (H x W x L) | 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) |
Weight | 340 g (12 oz) |
Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.
Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.
Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.
Click on a category to view a selection of compatible accessories with the Fluke V3000 FC Kit.